Berliner walls with timber lagging

Vertical steel beams with timber lagging between them, installed progressively with excavation in accordance with the approved design and sequence.

Service scope

Berliner walls

International Rafedah Piles Company constructs Berliner retaining walls using vertical steel beams and timber lagging to support excavation sides. The design defines the arrangement, details, excavation stages and any additional support.

Berliner walls

System concept; construction details are defined by the project design

System components

The principal elements are vertical steel beams and timber lagging installed between them. Drawings specify dimensions, details and installation requirements.

Installation with excavation

Excavation, lagging and additional support are coordinated through an approved sequence, with attention to ground conditions, groundwater and adjacent structures.

Assessing suitability

Ground conditions, excavation depth, loads, working space and adjacent structures are reviewed before adopting the system. Groundwater control requirements are assessed for the site.

How the Berliner wall works

Vertical steel beams form the principal retaining members, while timber lagging retains the ground between them. The distinction from a concrete infill wall lies in the infill material and connection details, rather than the presence of steel beams alone. Lagging installation is coordinated with the approved excavation stages. The design determines whether additional support is required for the loads and site conditions. Groundwater, weak ground and adjacent structures requiring closer movement control are considered when assessing suitability.

Coordinating the work on site

Coordination covers beam positions and levels, excavation boundaries, existing services and interfaces with foundations and subsequent works. Equipment access, working space and excavation sequence affect the construction programme. Lagging, voids behind the facing and connections are reviewed against project documents. Defining these interfaces early makes the scope clearer and helps coordinate support installation with equipment movement and construction activities inside the excavation.

Preparing the enquiry and defining the scope

Clear project information helps the proposal reflect the site requirements accurately. The company reviews available inputs and identifies missing information before the proposal defines the included works, supply and construction boundaries, coordination, inspections and records applicable to the project. Commercial comparison should consider levels, quantities, programme and interfaces rather than the price of an isolated item. Provide the available drawings and reports with the inputs below and identify whether the assignment requires a design study, construction to approved drawings or coordination of both stages. Access and working restrictions, responsibilities and approval points should also be stated so the next steps and expected deliverables are clear before the assignment begins.

  • Retaining lengths, excavation levels and ground strata
  • Available beam and timber lagging drawings
  • Equipment access, neighbouring buildings and services
  • Supply, installation and any agreed removal scope

Project questions

Before construction

Practical answers to help define the scope and prepare site information

What defines a Berliner wall?

The system uses vertical steel beams with timber infill between them. Dimensions, arrangement and installation details are established by the design.

Berliner walls use timber lagging between the steel beams. The other system uses concrete infill cast on site to its approved details.

A watertight barrier must not be assumed. Groundwater conditions and any dewatering or other control measures are assessed in the design.

This is defined by the proposal and project documents rather than assumed from the name Berliner wall. Beam interfaces with the permanent works, boundaries and construction programme are reviewed. Supply, installation and any agreed recovery or removal are identified in line with the design and relevant project requirements.

Commercial comparison follows an assessment of suitability for the ground, groundwater, loads and surrounding structures. A lower price may cover different lagging, support, construction stages, supply or removal requirements. Comparing equivalent scopes makes the technical and commercial differences clearer before a system is selected.

Retaining lengths, excavation levels, ground information and available drawings are provided with the required supply, installation, support, excavation and groundwater boundaries. Access, headroom and working constraints near buildings help the team review constructability, equipment requirements and the proposed programme.

The next step

Let’s review your site requirements

Share the available drawings, ground investigation report, excavation depth and required scope so we can discuss the requirements and next steps