Skip to content
RPCInternational Rafedah Piles Company

International Rafedah Piles Company

Shoring system design for excavation shoring

Review of site information, ground investigation data and loads to design the support system, details and construction stages within the agreed engineering scope.

Service scope

Shoring system design

International Rafedah Piles Company provides engineering design for excavation shoring. We review ground investigation data, levels, loads and adjacent buildings and utilities before comparing suitable systems and coordinating construction requirements.

Shoring system design

System concept; construction details are defined by the project design

The inputs behind the design

Ground conditions, groundwater, excavation depth and site boundaries influence system selection. Available information and missing inputs are identified before developing the engineering solution.

  • Ground investigation and groundwater information
  • Drawings, levels and excavation depth
  • Adjacent loads, buildings and utilities
  • Access, boundaries and construction stages

System selection and detailing

Support alternatives are compared against site conditions and project requirements. Element dimensions, connections, reinforcement, infill and any additional support are coordinated in the design.

Deliverables for construction

The appointment defines drawings, calculations, excavation stages, inspections, monitoring and approval procedures. Changes arising during construction are reviewed with the relevant project parties.

What the shoring design review covers

The design connects the excavation works with the structures and infrastructure that must be protected around them. The review covers boundaries, ground and foundation levels, soil or rock strata, groundwater and loads from nearby roads, buildings and equipment. Alternatives are considered alongside excavation sequencing, working space, installation access and any removal requirements. Excavation depth alone does not determine the solution: neighbouring structures, movement constraints and deformation control requirements can change the appropriate system.

From assessment to construction information

The agreed design scope defines the required deliverables: layouts and sections, support member arrangements, beam and infill details, reinforcement and connections, engineering calculations and construction stages. Interfaces with foundations, groundwater control and existing services are coordinated, and outstanding site information is identified before drawings are approved. Changes in ground conditions or levels during construction are reviewed for their effect on the overall system, rather than treated as isolated alterations.

Preparing the enquiry and defining the scope

Clear project information helps the proposal reflect the site requirements accurately. The company reviews available inputs and identifies missing information before the proposal defines the included works, supply and construction boundaries, coordination, inspections and records applicable to the project. Commercial comparison should consider levels, quantities, programme and interfaces rather than the price of an isolated item. Provide the available drawings and reports with the inputs below and identify whether the assignment requires a design study, construction to approved drawings or coordination of both stages. Access and working restrictions, responsibilities and approval points should also be stated so the next steps and expected deliverables are clear before the assignment begins.

  • Structure type, site layouts and property boundaries
  • Ground investigation, groundwater and excavation levels
  • Surrounding loads, access constraints and existing services
  • Required design deliverables, review and approval process

Project questions

Before construction

Practical answers to help define the scope and prepare site information

What information is needed to start?

Provide the ground investigation report, drawings, levels, excavation depth, loads and adjacent-site information. Identify missing information so the remaining inputs can be agreed.

Suitability varies with ground conditions, groundwater, loads, space and construction stages. Alternatives are compared before selecting a solution.

The proposal defines the required drawings, calculations, coordination, reviews and outputs, together with responsibilities and scope boundaries.

Each assignment defines the scope of its stages. The proposal identifies responsibility for drawings, calculations, review and approval and whether construction or site follow-up is included. Establishing these boundaries at the outset clarifies the deliverables and their coordination with the contractor, consultant and other project parties.

Changes are referred to the responsible designer with the revised levels, loads or site information. They may require a review of members, infill, construction stages or interfaces. A drawing is not assumed to remain appropriate after its design inputs change without assessing the effect of the revision.

Photographs help explain access, adjacent structures and working space. They do not replace ground investigation, drawings, levels or load information. Images are reviewed alongside the project data to identify what is known and what needs to be completed before the engineering solution and deliverables are developed.

The next step

Let’s review your site requirements

Share the available drawings, ground investigation report, excavation depth and required scope so we can discuss the requirements and next steps

WhatsApp