Skip to content
RPCInternational Rafedah Piles Company

International Rafedah Piles Company

Reinforced concrete pile walls for excavation shoring

Retaining walls formed with secant piles, contiguous piles, or spaced piles with shotcrete infill, according to the selected system and approved details.

Service scope

Reinforced concrete pile walls

International Rafedah Piles Company constructs reinforced concrete pile walls in three arrangements: secant piles, contiguous piles without overlap, and spaced piles with shotcrete infill. The design defines the arrangement, dimensions, reinforcement and construction sequence.

Reinforced concrete pile walls

System concept; construction details are defined by the project design

Selecting the arrangement

Ground conditions, groundwater, excavation depth, loads, adjacent structures and space inform the pile arrangement and any additional wall support.

Inspection and records

Requirements may cover pile positions, dimensions, depth, verticality, reinforcement, concrete and infill records, together with the agreed inspections and monitoring.

Three pile wall arrangements

The wall type depends on the relationship between neighbouring piles. Secant piles overlap to form a connected retaining arrangement in accordance with the design and construction sequence. Contiguous piles are placed adjacent to one another without the same overlapping arrangement. Spaced piles have intervening gaps addressed with shotcrete facing as part of the selected system. The design defines diameters, spacing, reinforcement, drilling and casting sequence and interface details. Groundwater requirements are assessed separately from the name of the wall type.

Selecting the arrangement for the project

Adjacent buildings, boundaries, ground strata, excavation depth and groundwater influence the comparison of pile wall alternatives. Equipment access, available headroom, working space and interfaces with the permanent structure also affect construction planning. Connections at pile heads and other support members, where required, are coordinated with the project execution and inspection records. General illustrations explain the system concept; approved project drawings remain the reference for actual site details.

Preparing the enquiry and defining the scope

Clear project information helps the proposal reflect the site requirements accurately. The company reviews available inputs and identifies missing information before the proposal defines the included works, supply and construction boundaries, coordination, inspections and records applicable to the project. Commercial comparison should consider levels, quantities, programme and interfaces rather than the price of an isolated item. Provide the available drawings and reports with the inputs below and identify whether the assignment requires a design study, construction to approved drawings or coordination of both stages. Access and working restrictions, responsibilities and approval points should also be stated so the next steps and expected deliverables are clear before the assignment begins.

  • Proposed pile arrangement and available drawings
  • Retaining lengths, diameters and design levels
  • Groundwater, strata and equipment constraints
  • Drilling, reinforcement, concreting, connections and infill scope

Project questions

Before construction

Practical answers to help define the scope and prepare site information

How do the three arrangements differ?

Secant piles overlap; contiguous piles are constructed next to one another without overlap; spaced piles have shotcrete infill between the separated piles.

The wall retains excavation sides and resists the lateral loads defined by the design, with project-specific embedment, support and verification requirements.

Performance depends on arrangement, verticality, depth, ground conditions and construction details. Dewatering or other groundwater measures may be required.

They describe different relationships between adjacent piles, with design-specific details and construction sequences. Spaced piles with shotcrete between them form another arrangement. A useful comparison identifies the required configuration, groundwater and neighbouring constraints, reinforcement and connections within a clearly defined scope.

Pile diameter, depth and strata are reviewed with available headroom, working space and access to the work front. Equipment is selected as part of the construction method review rather than on the wall name alone or an assumption that the same rig will suit every site.

Project documents define the construction and inspection records required for the piles, concrete, reinforcement and levels. The proposal clarifies the documentation and follow-up included in the scope. Record submission is coordinated with the consultant or responsible project party in accordance with the assignment requirements.

The next step

Let’s review your site requirements

Share the available drawings, ground investigation report, excavation depth and required scope so we can discuss the requirements and next steps

WhatsApp